Surface measurements

RTD Pt100 4 wiresSurface temperature probes
Single element
Tollerance Class 1/5 DIN
Simple insulation
Extension cable section 4×0.15 mm2 in Teflon, length 20 Meters
Sticky part in Fiberglass
Thermosetting Silicon adhesive
Contact force 420 cN/cm
Traction strenght 29.7 daN/cm
Processing range from -50 °C to +160 °C (intermittent exposition 180 °C)

RTD Pt100 ATEXPt100 atex for pipe
Max Temp. 250 °C
Single execution
Number of wires: 3
Class A, IEC751
Sheath diameter 6mm in AISI316
Simple insulation
Length 60mm
Head connection: Case ATEX EX d
Input conduit: 1/2” NPT Female
Standard Transmitter, 4/20 mA, (0/60) °C
Amb. Temperature [-25 °C to + 40 °C]
Process connection: AISI430 cable tie hose clamp for Tube from 70 to 90mm, width 9mm
Thermometric complex in compliance requirement directive 94/9/CE (ATEX) with certification

Thermoresistance Pt100 for surface surveyRTD Pt100 3 wires surface survey
Single 3 wires
Class A, as IEC751
Insulation by MgO compressed
Sheath diameter 6mm in AISI316, length 400mm
Head connection by aluminium DIN B
Transmitter SEM 203P, output 4-20 mA, configured 0…100 °C
Sliding compression fittings ½” NPT Male

Thermowell in AISI 316L
Inner hole 6,5mm
Immersion 300mm under flange
Total length 350mm

Thermocouple J typeThermocopuple J type with metal loop
Wire execution
Tolerance class 1, as IEC584 1,2
Contact Hot joint on metal loop
Extension cable section 2×0,22 mm2
Insulation: by fiberglass with armor in AISI304, length 2 meters
Metal Loop for screw M6 inserted directly on contact with Hot Jount of the thermocouple
External diameter 12mm, inner diameter 6,25mm